Water-heating boiler gas-fired RSH-100 (2х49kW)
  • Heat power: 98 kW

    Water temperature regulation range: +50..+95°C

    Max. heating agent pressure: 0,6 (optionally 1,0) MPa

    Fuel: gas

    Max.fuel consumption: (natural gas) 12,0 m³/hour

    Boiler water volume: 140..160 L

    Weight, no more: 1230 kg

    ORDER THE EQUIPMENT'S IN EXISTENCE

Gas-fired water-tube boiler for external installation, fully assembled inside of metal insulated block. The boiler equipped with atmospheric burner. The heat exchanger is made of finned tubes with high heat transfer surface.

Type of fuel:

  • Natural gas GOST 5542-87,
  • Liquefied petroleum gas LPG (propane-butane)

The complete set of the boiler for external installation includes:

  • boiler RSA series;
  • instruments (pressure control, water temperature control, gas low pressure control);
  • pipelines and valves.

Additional equipment for water-heating boiler is available optionally:

  • circulation pump, mesh filter (Y-strainer), safety valves;
  • methane gas contamination alarm;
  • thermal shut-off valve;
  • emergency signal transmission system via radio or to the owner's cell phone.
Heat power
       -natural gas kW 98
       -LPG kW 90
Instruments NOVA 820
Fuel type газ
ДInlet gas pressure before burner (natural gas):
       -minimum kPa 1
       -nominal kPa 2
       -maximum kPa
4
Inlet gas pressure before burner (LPG):
       -nominal kPa 3,7
Gas consumption max. (natural gas) m³/hour 12,0
Gas consumption min. (natural gas) m³/hour 6,0
Gas consumption nom. (LPG) m³/hour 10,3
Heating agent type  
drinking water GOST2874-73
Pressure loss in outlet pipeline after boiler
       -minimum
Pa 10
       -maximum Pa 40
Pump specification
       -model   NM-32/12DE,"Calpeda"
       -capacity m³/hour 10,0
       -head m WC 15,0
       -power kW 0,75
       -voltage V
220
Water working pressure MPa 0,6 (optionally 1,0)
Water temperature regulation range С° +50..+95
Min. water consumption throughout the boiler (according to «boiling prevention» clause) m³/hour 3,4
Boiler water volume L 20,1140..160
Max. allowable flow resistance of heating system m WC 22
Boiler flow resistance m WC 2,0
Connection thread:
       -inlet gas connection mm DN 32
       -nozzle for heating system connection mm DN 50
Smokestack size mm DN 200 (2 шт.)
Class of fire risk ГН
Ambient class У1
Ambient temperature С° -45..+40
Efficiency, no less % 93
Weight, no more kg 1230

Item
Equipment title
   
1
Gas pipeline
mm DN32
2
Smokestack
mm Ду200 (2шт.) 
3
Air inflowing gap
см² 520
4
Inlet pipeline
mm DN50
5
Outlet pipeline
mm DN50
6
Gas vent
mm DN25
7
Boiler\’s drainage
mm DN15
8
Safety relief valve
mm Ду15 (2шт.)
B

mm 1800
L

mm 2020
H

mm 1880
B1

mm 600
B2

mm 200
B3

mm 600
B4

mm 2020
L1

mm 875
L2

mm 340
L3

mm 560
L4

mm 120
L5

mm 815
L6

mm 550
L7

mm 265
L8

mm 2190
H1

mm 1945
H2

mm 1330
H3

mm 180
H4

mm 1705
H5

mm 1615